Settings for turning functions (# TURN)

This function is available as of CNC Build V3.1.3079.03.

The #TURN command can influence rotary functions.

Syntax:

#TURN [ [ROT_FEED_CPL=..] [TIME_IN_REV_CPL=..] [TAPPING_ACT_POS=..]
                  [TAPPING_N_CYCLES=..] [THREAD_CUT_ACT_SPEED =..]
                  [THREAD_CUT_N_CYCLES =..] [THREAD_CUT_IGNORE_OV =..]
                  [THREAD_CHAIN =..]]

ROT_FEED_CPL=..

Influence of axis couplings on the revolution feed rate with G95

0 : Axis couplings are not considered (default)

1 : Axis couplings are considered

TIME_IN_REV_CPL= ..

Influence of axis coupling on dwell time with G04

0 : Axis couplings are not considered (default)

1 : Axis couplings are considered

Available as of V3.1.3131.0

TAPPING_ACT_POS=..

Enable tapping at actual spindle positions.
(analogous to P-CHAN-00761)

0: The spindle is coupled to the command positions of the linear axis.

1: The linear axes are coupled to the actual spindle positions.

Available as of V3.1.3080.04

TAPPING_N_CYCLES=..

Number of filter cycles to filter actual spindle positions. (Analogous to P-CHAN-00762)

Value range: 0 … 20

0: Filter is deactivated.

Available as of V3.1.3080.04

THREAD_CUT_ACT_SPEED=..

Enable thread cutting at actual spindle speed. (Analogous to P-CHAN-00834)

0: The linear axes are coupled to the command spindle speed.

1: The linear axes are coupled to the actual spindle speed.

Available as of V3.1.3080.16

THREAD_CUT_N_CYCLES=..

Number of filter cycles to filter actual spindle speed. (Analogous to P-CHAN-00835)

Value range: 0 … 20

0: Filter is deactivated.

Available as of V3.1.3080.16

THREAD_CUT_IGNORE_OV=..

During thread cutting G33 it can be specified whether an evaluation of the speed override should take place (analogous to P-CHAN-00836)

0: Override changes are included in the thread cutting block G33

1: Override changes are not included in the thread cutting block G33

Available as of Build V3.1.3081.11 or V3.1.3118.0

THREAD_CHAIN=..

Thread chain: Linking and contouring G33 thread cutting blocks (analogous to P-CHAN-00837)

0: Each thread cutting block G33 is processed separately and synchronised with the spindle axis before every thread cutting operation

1: The following thread cutting blocks are regarded as a thread chain. Contouring takes place between the thread cutting blocks G33 without motion stop.

Available as of Build V3.1.3081.11 or V3.1.3118.0