Generate compensation blocks
The generation of compensation blocks is not subject to restrictions with respect to the NC block sequence as applies to direct or indirect TRC selection. The next block after the current block is used to calculate contour transitions between the programmed NC blocks.
The contour transition is on straight lines (G25) by default – or optionally on arcs (G26) – with the option of feed rate adaptation (G10/G11).
The table below and the supplementary diagrams show all the possible contour transitions, whereby both the possible transitions (linear and circular interim blocks) are shown.
Insert blocks by the TRC LIN: Linear block, CIR: Circular block G25: Insert linear transition G26: Insert circular transition (2 LIN : The TRC inserts 2 linear blocks at the transition). | ||||||
| Angle range | |||||
| 0° to 180° | 180° to 270° | 270° to 360° | |||
progr. block sequence | G25 | G26 | G25 | G26 | G25 | G26 |
LIN-LIN | 0 | 0 | 0 | 1 CIR | 1 LIN | 1 CIR |
LIN-CIR / CIR-LIN | 0 | 0 | 1 LIN | 1 CIR | 2 LIN | 1 CIR |
CIR-CIR | 0 | 0 | 2 LIN | 1 CIR | 3 LIN | 1 CIR |


Combination type 1: 0° < ß ≤ 180°, G41 | Combination type 3: 0° < ß ≤ 180°, G41 |
|
|
Combination type 2: 0° < ß ≤ 180°, G41 | Combination type 4: 0° < ß ≤ 180°, G41 |
|
|
TRC transitions: Combination cases for 0° < ß ≤180 ° (independent of G25 or G26 since no compensation blocks are added)
Combination type 1: 180° < β ≤ 270°, G41 | Combination type 3: 180° < β ≤ 270°, G41 |
|
|
Combination type 2: 180° < β ≤ 270°, G41 | Combination type 4: 180° < β ≤ 270°, G41 |
|
|
TRC transitions: Combination cases for 180° < ß ≤ 270° with linear interim blocks
Combination type 1: 270° < ß ≤ 360°, G41 | Combination type 3: 270° < ß ≤ 360°, G41 |
|
|
Combination type 2: 270° < ß ≤ 360°, G41 | Combination type 4: 270° < ß ≤ 360°, G41 |
|
|
TRC transitions: Combination cases for 270° < ß ≤ 360° with linear interim blocks
Combination type 1: 180° < β ≤ 270° , G41, G26 | Combination type 3: 180° < β ≤ 270° , G41, G26 |
|
|
Combination type 2: 180° < β ≤ 270° , G41, G26 | Combination type 4: 180° < β ≤ 270° , G41, G26 |
|
|
TRC transitions: Combination cases for 180° < ß ≤ 270° with circular interim blocks
Combination type 1: 270° < ß ≤ 360°, G41, G26 | Combination type 3: 270° < ß ≤ 360°, G41, G26 |
|
|
Combination type 2: 270° < ß ≤ 360°, G41, G26 | Combination type 4: 270° < ß ≤ 360°, G41, G26 |
|
|
TRC transitions: Combination cases for 270° < ß ≤ 360° with circular interim blocks



















