Programming
Syntax: | |
#EXTCOMP ON/OFF [ID=.. STRING=.. VALUE=..] | |
ID=.. | Compensation number |
STRING=<string> | Optional additional information for the compensation as string |
VALUE=.. | Optional additional information for the compensation as numeric value |
The compensation can be switched on or off in the NC program. An additional option is that a message consisting of a string 24 characters long and a REAL value can be sent via the NC program to the compensation.
Programming Example
%Example1
N010 G01 X10 Y10 F1000
N020 #EXTCOMP [ID0 STRING=”OP1” VALUE=41]
N030 #EXTCOMP ON [ID0]
N040 G90 G01 X10 Y10 Z0 F1000
N050 G201 X1 Y1
N060 #EXTCOMP OFF [ID0]
Programming Example
Send a message to enable the compensation
%Example2
N010 G01 X10 Y10 F1000
N020 #EXTCOMP ON [ID0 STRING=”OP1” VALUE=41]
N030 G90 G01 X10 Y10 Z0 F1000
N040 G201 X1 Y1
N050 #EXTCOMP OFF [ID0]