Programming
The NC command #INSERT CMD can be used to specify stop marks via the NC program.
The "AXNR" parameter is used to set the mode.
- AXNR = 0 – DISTANCE mode (default)
- AXNR !=0 – POSITION mode
Syntax: | |
#INSERT CMD [ON | OFF] [AXNR=.. MNR=.. ADDR=.. DIST=.. [ABS | REL | REL_ONCE] ] | |
| |
ON | Insert stop marks is enabled |
OFF | Insert stop marks is disabled. This results in a stop at the program position. |
AXNR=.. | Logical axis number Stop is inserted at the commanded axis position of the axis with this logical axis number. Note: Mode is defined by specifying the logical axis number. AXNR = 0 – DISTANCE mode is used AXNR !=0 – POSITION mode is used Default value = 0 |
MNR=.. | Number of the inserted M function
|
ADDR=.. | Optional additional value of the M function; it is specified as a negative or positive integer. |
DIST=.. | Relative/absolute distance or axis position in [0.1µm] at which the stop is to be inserted. |
ABS | One-off insertion at the absolute distance |
REL | for relative distance with automatic insertion of a new stop when the current stop is reached. |
REL_ONCE | One-off insertion at the relative distance. |
![]() | The distance specification ABS/REL or REL_ONCE are mutually exclusive. When you use simultaneous programming within an #INSERT CMD instruction, the error is output with ID 22130. |
The default assignment of the NC command is:
#INSERT CMD [MNR=0 DIST=0 REL AX=0]
If M function < 2 is specified, the command for continuing machining must be given by the "Continue motion" control unit after the STOP is reached.
If M function is specified >= 2, the default acknowledgement of the M function is sufficient.
The bit in the stop conditions is displayed on the HLI when an inserted stop is reached.
The combination of the parameters DIST=0 and REL=1 clears the previously set STOP irrespective of the parameters MNR and AXNR,
The current distance can be reset with #DISTANCE PROG START CLEAR.