Parameterisation
Homing is parameterised axis-specific in the axis parameter list of an axis. This is divided depending on its task into:
- system parameters and
 - sequence parameters
 
System parameters
System parameters are used to make machine-specific settings in the drive system. The controller is notified of the information below in these parameters:
- Is the axis equipped with reference cams?
 - Is zero pulse or cam signal used for referencing?
 - What signal level does the cam supply in operated state?
 
Sequence parameters
The sequence parameters define the response during homing. This includes, for example:
- The velocity at which motion takes place in each of the homing phases.
 - The motion direction in which homing is started or executed.
 - The number of phases (single-phase or multi-phase) up to referencing.
 
Effectiveness of parameters
The section “Effectiveness of parameters” provides an overview of the effectiveness of homing parameters depending on the homing strategy used.