Status information time-to-distance

Calculated running time

Description

Time calculated for the specified length.

The validity of the calculated running time is indicated by the related valid flag with the same index.

Signal flow

CNC →PLC

ST path

gpCh[channel_idx]^.bahn_state.time_to_distance[ ]

Data type

ARRAY[0..9] OF DINT

Unit

[µs]

Access

PLC is reading

Special feature

Available as of CNC Build V3.1.3105

Calculated running time is valid

Description

This data item indicates the validity of the calculated running time with the same index.

Signal flow

CNC →PLC

ST path

gpCh[channel_idx]^.bahn_state.time_to_distance_valid[ ]

Data type

ARRAY[0..9] OF BOOL

Value range

TRUE/FALSE

Access

PLC is reading

Special feature

Available as of CNC Build V3.1.3105

Enlacement

Description

Current enlacement

Signal flow

CNC →PLC

ST path

gpCh[channel_idx]^.bahn_state.enlacement

Data type

UDINT

Unit

[0.1 µm]

Access

PLC is reading

Special feature

Available as of CNC Build V3.1.3105

Edge velocity

Description

Velocity at which the belt passes the energy input point.

Signal flow

CNC →PLC

ST path

gpCh[channel_idx]^.bahn_state.edge_velocity

Data type

DINT

Unit

[µm/s]

Access

PLC is reading

Special feature

Available as of CNC Build V3.1.3105

Edge distance

Description

Edge length that already passed the energy input point.

Signal flow

CNC →PLC

ST path

gpCh[channel_idx]^.bahn_state.edge_position

Data type

DINT

Unit

[0.1 µm]

Access

PLC is reading

Special feature

Available as of CNC Build V3.1.3105