Overview
ID | Parameter | Description |
|---|---|---|
P-AXIS-00230 | lr_hw[i].vz_istw | Sign reversal of actual sensor values |
P-AXIS-00328 | lr_param.distance_control_on | Enabling of distance control |
P-AXIS-00413 | kenngr. dist_ctrl[i].n_cycles | Smoothing of sensor data |
P-AXIS-00414 | kenngr.dist_ctrl[i].max_deviation | Maximum position offset [0.1 µm] |
P-AXIS-00415 | kenngr. dist_ctrl[i].v_max | Maximum permissible velocity for distance control [µm/s] |
P-AXIS-00416 | kenngr. dist_ctrl[i].a_max | Maximum permissible acceleration for distance control [mm/s^2] |
P-AXIS-00417 | kenngr. dist_ctrl[i].max_act_value_change | Maximum permissible change speed of measured distance [0.1 µm/cycle] |
P-AXIS-00418 | kenngr. dist_ctrl[i].ref_offset | Offset to reference point |
P-AXIS-00419 | kenngr. dist_ctrl[i].max_pos | Upper limit of sensor |
P-AXIS-00420 | kenngr. dist_ctrl[i].min_pos | Lower limit of sensor |
P-AXIS-00421 | kenngr. dist_ctrl[i].tolerance | Tolerance band |
P-AXIS-00422 | lr_hw[i].encoder_resolution_num | Resolution of the sensor measuring system (numerator) [increments] |
P-AXIS-00423 | lr_hw[i].encoder_resolution_denom | Resolution of the sensor measuring system (denominator) [0.1 µm] |
P-AXIS-00424 | lr_hw[i].mode_act_pos | Definition of the sensor value range: Linear scale or modulo handling of sensor values |
P-AXIS-00428 | kenngr. dist_ctrl[i]. check_sw_limit_switch | Consideration of the calculated offset of distance control in software limit switch monitoring |
P-AXIS-00500 | kenngr. dist_ctrl[i]. | Option: distance sensor and motor encoder |
P-AXIS-00501 | kenngr. dist_ctrl[i]. | Option: weighting of acceleration as a function of distance deviation. |
P-AXIS-00502 | kenngr. dist_ctrl[i].a_min | |
P-AXIS-00504 | kenngr. dist_ctrl[i].dist_error_a_min | |
P-AXIS-00505 | kenngr. dist_ctrl[i].dist_error_a_max | |
P-AXIS-00507 | kenngr. dist_ctrl[i].low_pass_filter_order | Smoothing of sensor data
|
P-AXIS-00508 | kenngr. dist_ctrl[i].low_pass_filter_fg_f0 | |
P-AXIS-00509 | kenngr. dist_ctrl[i].optimized_scheduling | Option: dead time reduction |
P-AXIS-00533 | kenngr. dist_ctrl[i].v_weight_down | Option: dynamic weighting for the lowering movement |
P-AXIS-00534 | kenngr. dist_ctrl[i].a_weight_down | |
P-AXIS-00759 | kenngr. dist_ctrl[i].kp | Weighting the distance control output values |
P-AXIS-00764 | kenngr. dist_ctrl[i].i_tn | Integral action time of the PID controller |
P-AXIS-00765 | kenngr. dist_ctrl[i].d_tv | Derivative action time of the PID controller |
P-AXIS-00782 | kenngr. dist_ctrl[i].filter_type | Smoothing of sensor data |
P-AXIS-00783 | kenngr. dist_ctrl[i].kalman_sigma | |
P-AXIS-00784 | kenngr. dist_ctrl[i].smoothing_factor | |
P-AXIS-00868 | kenngr.dist_ctrl[i].window | Tolerance window in which the control deviation must be in order to fulfil the waiting condition. |
P-AXIS-00869 | kenngr.dist_ctrl[i].cycles_in_window | Number of cycles that the control deviation must remain within the tolerance window in order to fulfil the waiting condition. |
P-AXIS-00870 | kenngr.dist_ctrl[i].max_wait_time | Maximum permissible waiting time to fulfil the waiting condition |