ID 70625
No compensation value list available for crosstalk compensation. | ||||
Description | The function crosstalk compensation (P-AXIS-00789) was selected for an axis in the axis parameters; however, the compensation value list containing the necessary correction values is missing. | |||
Response | Class | 7 | Controlled axis stop and disable crosstalk compensation | |
Solution | Class | 7 | If crosstalk compensation is enabled for an axis, a compensation value list must also be specified for it in the start-up list P-STUP-00016,, P-STUP-00017, P-STUP-00036). Example (extract from start-up list): zahl_kw 1 achs_kw[0] ..\listen\achskw3.lis achs_kw_log_ax_nr[0] 3 | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of axis affected, see P-AXIS-00016 | ||||
Error type | 11, Error message from position controller. | |||
| ||||