ID 110661
Kalman-Sigma P-AXIS-00783 for distance control is out of permissible range. | ||||
Description | The degree of uncertainty of the recorded measured values P-AXIS-00783 for the Kalman filter of the distance control may not exceed the specified limits. | |||
Response | Class | 1 | Output the warning and limit P-AXIS-00783 | |
Solution | Class | 1 | Check and modify P-AXIS-00783. Update the parameters | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number (P-AXIS-00016) of concerned axis | ||||
%2: | Error value [-] | |||
| ||||
%4: | Upper limit value [-] | |||
| ||||
%5: | Corrected value [-] | |||
If P-AXIS-00783 exceeds the maximum, the upper limit is output. If P-AXIS-00783 undershoots the minimum, the lower limit is output. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||