ID 22142
Order of the low-pass filter of distance control is out of data format. | ||||
Description | When the sensor values for distance control are filtered, the order for the low-pass filter can be specified by the keyword "DISTC_ORDER". The number exceeds the permissible data format. Further information on programming distance control in [FCT-M3// Programming] | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify the value for “DISTC_ORDER” in the NC program. | |
Parameter | %1: | Error value [-] | ||
Incorrectly programmed value for “DISTC_ORDER” | ||||
%2: | Lower limit value [-] | |||
Lower limit value for “DISTC_ORDER" | ||||
%3: | Upper limit value [-] | |||
Upper limit value for “DISTC_ORDER” | ||||
Error type | 1, Error message from NC program. | |||
| ||||