ID 70595
Filter for function Improved Position Control could not be generated. | ||||
Description | Several filters must be initialised for the Improved Position Control function. It was not possible to initialise a relevant filter. | |||
Response | Class | 7 | Controlled halt of the axis, the control loop is closed.. The Improved Position Control function is disabled. | |
Solution | Class | 6 | Check and correct the filter parameters | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected. | ||||
%2: | Instance [-] | |||
Step where it was impossible to initialise the filter. | ||||
%3: | Current value [-] | |||
Further information why the filter could not be initialised. | ||||
%4: | Error value [-] | |||
Filter type could not be initialised. | ||||
%5: | Status [-] | |||
The Improved Position Control function is disabled by P-AXIS-00758. | ||||
Error type | 11, Error message from position controller. | |||
| ||||