ID 13553
Incomplete or invalid vector of rotary axis when defining the inclination of probe. | |||
Description | A definition of the inclination by a rotary axis is required with the parameters @P94, @P95 and @P96 to adapt the inclination and measurement motions at the beginning of the cycle. The rotary axis is defined as a vector, where @P94 is defined as the X component, @P95 the Y component and @P96 the Z component. The vector must have a length greater than 0. Here, an approximate parameter is sufficient. The values are only used to estimate the measurement movement. | ||
Response | Class | 2 | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | 3 | Complete definition of the inclination of the probe by a rotary axis with the parameters @P94, @P95 and @P96. |
Error type | 1, Error message from the NC program | ||
| |||