ID 13552
Incomplete or invalid vector of rotary axis. | |||
Description | A complete definition of the expected rotary axis is required with the parameters @P91, @P92 and @P93 to adapt the measurement movements to the rotation of the rotary axis to be measured. The rotary axis is defined as a vector, where @P91 is defined as the X component, @P92 the Y component and @P93 the Z component. The vector must have a length greater than 0. Here, an approximate parameter is sufficient. The values are only used to estimate the measurement movement. | ||
Response | Class | 2 | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | 3 | Complete definition of the expected rotary axis with the parameters @P91, @P92 and @P93. |
Error type | 1, Error message from the NC program | ||
| |||