ID 22053
Couple kinematics: Kinematics name specified in tool data cannot be found in channel parameter list. | ||||
Description | The kinematic name specified in the tool data (P-TOOL-00148) must be identical with a kinematic name in the kinematic chain (P-CHAN-00449) of the active couple kinematic. Alternatively, P-TOOL-00148 may also contain an empty string. In this case, the tool is switched to the kinematic with the highest index in the first group. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Correct the kinematic name specified in the tool data. | |
Parameter | %1: | Current value [-] | ||
Kinematic ID configured in the tool data | ||||
%2: | Error value [-] | |||
Kinematic name configured in the tool data | ||||
Error type | 1, Error message from NC program. | |||
| ||||