ID 22027
Channel parameters: Parallel definition of the fixed rotary axis by "fixed_axis_idx" and "tool_ax_in_plane" is not allowed. | ||||
Description | The channel parameters ori.fixed_axis_index (P-CHAN-00178) and ori.tool_ax_in_plane (P-CHAN-00436) may not have the identical setting. | |||
Response | Class | 1 | Warning is output and correct the parameter. | |
Solution | Class | 1 | Check and modify the parameters P-CHAN-00178 and P-CHAN-00436. | |
Parameter | %1: | Current value [-] | ||
Parameterised value for ori.fixed_axis_index (P-CHAN-00178) | ||||
%2: | Current value [-] | |||
Parameterised value for ori.tool_ax_in_plane (P-CHAN-00436) | ||||
%3 | Corrected value [-] | |||
New value for P-CHAN-00178 | ||||
%4 | Corrected value [-] | |||
New value for P-CHAN-00436 | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||