ID 22014
Missing meas signal in trafo axis. Calculation of meas values not possible. | ||||
Description | Measurement with an active Cartesian or kinematic transformation supplies no measurement values although a measuring signal was latched in the programmed measurement axes. | |||
Response | Class | 1 | NC programming is continued without adoption of measurement values. | |
Solution | Class | 1 | A value is latched in the PLC for each axis involved in the transformation, not only for the programmed measurement axes. Only if a value is available for all trafo axes can the PCS measurement values be calculated,. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of the trafo axis which is missing a measuring signal or latched value. | ||||
Error type | 1, Error message from NC program. | |||
| ||||