ID 21970

An axis moving to fixed stop may not be released.

Description

An axis that is active for the Move to fixed stop function (see [FCT-M8]) cannot be released. The function must be deactivated before release.

 

Example with error:

N10 G01 X100 F1000 X[FIXED_STOP ON]
N30 #PUT AX [X] (Error 21970)

 

Possible solution:

N10 G01 X100 F1000 X[FIXED_STOP ON]
N20 G01 X0 X[FIXED_STOP OFF]
N30 #PUT AX [X]

Response

Class

2

Abort NC program processing. Transition to error state.

Solution

Class

3

Check and modify NC program.
Deselect the Move to fixed stop function before releasing the axis.

Parameter

%1

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2

Error value [-]

State of the Move to fixed stop function

Error type

1, Error message from NC program.