ID 292006
Kinematic transformation: Transformation not available. | ||||
Description | With this kinematic type, an auxiliary function is not supported with active kinematic transformation (#RTCP ON, #TRAFO ON). Example: Use of #TOOL ORI CS in tripod kinematics. Wrong: %trafo N10 KIN ID[12] N20 #TRAFO ON N20 #TOOL ORI CS N30 G01 G90 X0 Y0 Z100 F2000 N40 M30 Correct: %trafo N10 KIN ID[1] N20 #TRAFO ON N20 #TOOL ORI CS N30 G01 G90 X0 Y0 Z100 F2000 N40 M30 For more information on kinematic transformation, see | |||
Response | Class | - | Depending on the module where error occurs:
| |
Solution | Class | - | Do not use the utility function with this kinematic type. | |
Parameter | %1: | Current value [-] | ||
ID of incorrectly configured kinematic | ||||
%2: | Current value [-] | |||
Internal ID of error cause (only for diagnosis by specialists) | ||||
Error type | - | |||
| ||||