ID 120742
Independent axis movement not permitted for axes belonging to an active work or protection area. | ||||
Description | Axes belonging to an active workspace or protection area may not be moved by an independent axis movement (see FCT-C14). This also includes lift movements. For further information, see:
Example: #CONTROL AREA BEGIN [ID1 PROT POLY MIN_EXCUR=0 MAX_EXCUR=360]
G01 F1000 G90
X = 0 Y = 0
X = 0 Y = 100
X = 100 Y = 100
X = 100 Y = 0
X = 0 Y = 0
#CONTROL AREA END
#CONTROL ARA ON [ID1]
Independent axis movement not permitted for axes of an active work or protection area.
| |||
Response | Class | 2 | Output error message and abort NC program | |
Solution | Class | 6 | Correct the NC program | |
Parameter | %1: | Current value [-] | ||
ID of affected workspace or protection space | ||||
%2: | Current value [-] | |||
Relevant axes for control area | ||||
%3: | Incorrect value [-] | |||
Currently axis moving independently | ||||
Error type | 1, Error message from NC program. | |||
|