ID 120586

Necessary function of path preparation not enabled in CNC configuration list.

Description

In the start-up parameters, the CNC system is configured in terms of the number of channels, number of axes in the system, etc. The number of axes in the system is set by the CNC. In addition, the active functions of path preparation for each channel can also be defined with P-STUP-00060. With this parameters, the system can be tuned for minimising runtime and memory size in multi channel systems, depending on the requirements of the user. All required basic functions are activated in the default setting.

In the present case, a function was used in the NC program that is deactivated in the start-up list or is not activated as a default function.

Alternatively, a channel can be parameterised using P-CHAN-00600.

Response

Class

2

Abort NC program processing.

Solution

Class

7

Correct the NC program or set the configuration using P-STUP-00060

Parameter

%1:

Expected value [-]

Missing function in P-STUP-00060

%2:

Expected value [-]

Missing internal function ID

%3:

Current value [-]

Currently active internal functions

%4:

State [-]

Control block-ID of programmed function

Error type

1, Error message from NC program.