ID 120567
Changing definition of feed axis impossible while polynomial contouring is active. | ||||
Description | Feed rate mapping on axes may not be changed while contouring mode is active (see #FGROUP). | |||
Response | Class | 2 |
| |
Solution | Class | 6 | Check default setting in channel list P-CHAN-00011 or #FGROUP programming. | |
Parameter | %1: | Logical axis number [-] | ||
| ||||
%2: | NC block number [-] | |||
Number of previous block in block transition | ||||
%3: | Current value [-] | |||
Setting in the current block that indicates whether the axis is involved in feed rate mapping. | ||||
%4: | Expected value [-] | |||
Setting in the previous NC block that indicates whether the axis is involved in feed rate mapping. | ||||
Error type | 1, Error message from NC program. | |||
| ||||