ID 120480
The second block to define a circular area must be circular. | ||||
Description | The second motion block after starting a definition of a circular area must be a circular block for the circular description of the area. A circular area definition consists of two motion blocks, one linear at the starting point, and one circular to describe the circle See also [PROG// Monitoring the workspace and protection space] and [FCT-C14// Description].
Example: %circular area N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU… N20 G01 X150 Y200 F10000 N30 G01 X150 Y200 F10000 N40 #CONTROL AREA END N50 M30 (> error Solution: %circular area N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU… N20 G01 X150 Y200 F10000 (start point) N30 G02 G162 I70 J150 N40 #CONTROL AREA END N50 M30 (> correct) | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 6 | Check and modify the area definition in the NC program. | |
Parameter | %1: | Identification number [-] | ||
Area ID | ||||
Error type | 1, Error message from NC program. | |||
| ||||