ID 120480

The second block to define a circular area must be circular.

Description

The second motion block after starting a definition of a circular area must be a circular block for the circular description of the area.

A circular area definition consists of two motion blocks, one linear at the starting point, and one circular to describe the circle See also [PROG// Monitoring the workspace and protection space] and [FCT-C14// Description].

 

Example:
%circular area
N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU…
N20 G01 X150 Y200 F10000
N30 G01 X150 Y200 F10000
N40 #CONTROL AREA END
N50 M30
(> error
Solution:
%circular area
N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU…
N20 G01 X150 Y200 F10000 (start point)
N30 G02 G162 I70 J150
N40 #CONTROL AREA END
N50 M30
(> correct)

Response

Class

2

Abort NC program processing.

Solution

Class

6

Check and modify the area definition in the NC program.

Parameter

%1:

Identification number [-]

Area ID

Error type

1, Error message from NC program.