ID 120473
Active area can not be overwritten, area is not saved. | ||||
Description | An attempt was made to overwrite an active area. Overwrite areas means to define an area with the same existing ID. See also [PROG// Defining a control area] and [FCT-C14// Description].
An area already exists with the commanded ID and it is currently activated. To overwrite an existing area, it should be inactive.
Example with error: %areaoverwrite N10 #CONTROL AREA ON [ID2] N20 #CONTROL AREA BEGIN [ID2 WORK ……… (< error Corrected example: %areaoverwrite N10 #CONTROL AREA ON [ID2] N15 #CONTROL AREA OFF [ID2] N20 #CONTROL AREA BEGIN [ID2 WORK.. (< overwrite | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 6 | Check and modify NC program; deactivate the area to be overwritten. | |
Parameter | %1: | Identification number [-] | ||
Area ID | ||||
Error type | 1, Error message from NC program. | |||
| ||||