ID 120462
Feed axis transformation with selected axis group not possible. | |||
Description | The restrictions must be taken into account for the definition of feed axis groups (#FGROUP) in connection with polynomial and circular motions. Regardless of the #FGROUP command, the following commands / functions always use the first two or three axes as path feed axes:
- Polynomial contouring, G61, G261 - Spline function, G151 - HSC function, #HSC[ON]
With circular motion G02, G03, either only circular axes (and helical axis) are feed axes or the other axes are feed axes.
For more information on feed groups, | ||
Response | Class | 1 | None. |
Solution | Class | 1 | Define feed axis group with the first two or three axes depending on axis configuration. |
Error type | 1, Error message from NC program. | ||
|