ID 120297
Flushing buffers not allowed while polynomial contouring is active. | ||||
Description | While polynomial contouring (G61, G161), is active, it is not possible to execute any selection or deselection functions which may cause flushing of the CNC channel. These include the following CNC commands / functions, for example: - #FLUSH, #FLUSH CONTINUE, #FLUSH WAIT - #CHANNEL INIT, #SET DEC LR SOLL - #GET CMDPOS, #SET IPO SOLLPOS - #CS ON[], CS OFF - #TRAFO ON/OFF - G200 - Reading synchronous V.E variables
For more information on polynomial contouring interpolation and the listed commands, see | |||
Response | Class | 2 | Program abort. | |
Solution | Class | 6 | Do not use any of the commands listed above when polynomial contouring is active. | |
Parameter | %1: | Current value [-] | ||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||