ID 120213
Corrected programmed feed rate due to stroke of probe. | ||||
Description | In combination with the measuring function G100, different measurement types can be selected via the machine channel parameters (P-CHAN-00057) or CNC programming (#MEAS MODE). With measurement modes 2 und 4, the feedrate measurement is automatically reduced so that value of braking distance can be stopped within the probe stroke P-AXIS-00086. For more information on measurement function see | |||
Response | Class | 1 | None | |
Solution | Class | 1 | Check permissible stroke of measuring probe P-AXIS-00086 and dynamic characteristics
measurement type type 2: Reduce measurement feed in axis parameter list P-AXIS-00215. measurement type type 4: Reduce measurement F word in CNC program. | |
Parameter | %1: | Corrected value [1µm/s or 0,001°/s] | ||
| ||||
%2: | Logical axis number [-] | |||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||