ID 120140
Too many non-relevant blocks in sequence while polynomial contouring is active. | |||
Description | In the CNC program, there are too many non-relevant blocks between two motion blocks to be connected by polynomial contouring (G61, G261). Non-relevant blocks are all CNC program blocks that contain no motion. These are, for example, blocks that result from subroutine calls or parameter calculations. Too many non-relevant blocks exceed the capacity of the internal buffer memory and polynomial contouring cannot be calculated. For further information, see [PROG// Section: Polynomial contouring]. | ||
Response | Class | 2 | Program abort. |
Solution | Class | 6 | Check CNC program, reduce subroutine calls and parameter calculation between polynomial contouring motion blocks. |
Error type | 1, Error message from NC program. | ||
| |||