ID 120107
Too many non-relevant blocks in sequence while spline is active. | |||
Description | The CNC program contains too many non-relevant blocks between two motion blocks to be connected by spline interpolation. Non-relevant blocks are all CNC program blocks that contain no motion. These are, for example, blocks resulting from M function subroutine calls or parameter calculations. With too many non-relevant blocks, internal buffer memory is not sufficient and spline interpolation cannot be executed. The spline is activated by:
For more information on spline interpolation, see | ||
Response | Class | 2 | Program abort. |
Solution | Class | 6 | Check CNC program, reduce the number of M functions, subroutine calls and parameter calculations between spline interpolation motion blocks. |
Error type | 1, Error message from NC program. | ||
| |||