ID 120027
Acceleration step 1 is greater than maximum acceleration. | ||||
Description | The axis acceleration can be weighted with G functions G130, G131. The weighted axis acceleration value step 1 P-AXIS-00011 of linear slope exceeds limit of maximum permissible axis acceleration P-AXIS-00008. The weighted value is limited to the maximum permissible axis acceleration. For further information, see [PROG// Section: Acceleration weighting]. | |||
Response | Class | 1 | None | |
Solution | Class | 1 | Keep programmed acceleration weighting within valid range. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected. | ||||
%2: | Current value [1mm/s^2 or 1°/s^2] | |||
Weighted value of acceleration level 1 P-AXIS-00011. | ||||
%3: | Upper limit value [1mm/s^2 or 1°/s^2] | |||
Maximum permissible axis acceleration P-AXIS-00008. | ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| ||||