ID 110540
Coarsening factor for encoder resolution exceeds valid range of values. | ||||
Description | The axis parameter P-AXIS-00405 can be used to coarsen the encoder resolution of the drive. The given value is however invalid. | |||
Response | Class | 1 | Warning and correct parameter P-AXIS-00405 | |
Solution | Class | 1 | Correct parameter P-AXIS-00405 | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected | ||||
%2: | Drive type [-] | |||
Drive type P-AXIS-00020 of the affected axis | ||||
%3: | Incorrect value [-] | |||
Incorrect value for coarsening factor P-AXIS-00405 | ||||
%4: | Upper limit value [-] | |||
Maximum permissible value for coarsening factor P-AXIS-00405 | ||||
%5: | Corrected value [-] | |||
Corrected value for coarsening factor P-AXIS-00405 | ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| ||||