ID 110533
Sign of actual value and set value must be changed jointly. | ||||
Description | In the operation mode of an axis P-AXIS-00015, if ALLOW_RESOLUTION_CHANGE = 0x400000 is set, the value of parameters P-AXIS-00230 and P-AXIS-00231 for the sign reversal of manipulated variable and actual value can be changed by updating the axis parameter list. However, in order to prevent a runaway of the drive from running through, these two parameters can only be changed together. | |||
Response | Class | 1 | Warning, no acceptance of new parameter P-AXIS-00230 and P-AXIS-00231 | |
Solution | Class | 1 | Only change sign of manipulated variable and actual value jointly. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Current value [-] | |||
Current value for sign reversal of actual value P-AXIS-00230 | ||||
%3: | Current value [-] | |||
Current value for sign reversal of manipulated variable P-AXIS-00231 | ||||
%4: | Error value [-] | |||
New, invalid value for sign reversal of current value P-AXIS-00230 | ||||
%5: | Error value [-] | |||
New, invalid value for sign reversal manipulated variable P-AXIS-00231 | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||