Not enough memory available for the compensation list. |
Description | There are two possible causes for this error message: - A compensation value list was assigned in P-STUP-00036 for axis compensations. However, the CNC was unable to allocated the required memory from the operation system. A possible solution is to delete the compensation value list or increase the available memory.
- A compensation value list was not assigned to the axis in the start-up list with P-STUP-00036 but a compensation value list was still loaded during the controller runtime. A solution in this case is to add a compensation value list for this axis P-STUP-00036 in the start-up list.
|
Response | Class | 3 | Start-up of CNC is aborted |
Solution | Class | 7 | Delete compensation value list or increase available memory. |
Parameter | %1: | Logical axis number [-] |
Logical axis number P-AXIS-00016 of axis affected. |
%2: | Error value [Byte] |
Requested memory size |
Error type | - |
|