ID 110418
Value for parameter encoder_range is outside permissible range. | ||||
Description | Parameter P-AXIS-00296 is out of the permissible range. | |||
Response | Class | 1 | Warning output, correct the value of P-AXIS-00296. If P-AXIS-00296 was configured below the minimum value, P-AXIS-00296 is set to the minimum value, otherwise, if the maximum value was exceeded, P-AXIS-00296 is limited to the maximum value. | |
Solution | Class | 1 | Set a valid value for P-AXIS-00295 in the axis parameter list. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of affected axis (see P-AXIS-00016). | ||||
%2: | Current value [-] | |||
Index of the invalid entry in the lr_hw[] array. A value of 0 means lr_hw[0].encoder_range is incorrect. | ||||
%3: | Lower limit value [-] | |||
| ||||
%4: | Upper limit value [-] | |||
| ||||
%5: | Corrected value [-] | |||
| ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| ||||