ID 110218
Illegal grating of correction value intervals. | ||||
Description | The step size between 2 interpolation points from the list of compensation values for leadscrew error compensation is specified in parameter P-COMP-00018.
The message is displayed because the value for the interval is < 0. | |||
Response | Class | 3 | Correction of the value | |
Solution | Class | 7 | Check and modify the parameter P-COMP-00018. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Error value [Incr.] | |||
The CNC uses this value for parameter P-COMP-00009 instead of the value indicated by the user. | ||||
%3: | Lower limit value [Incr.] | |||
| ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||