ID 90178

Illegal combination of parameters in multipath configuration.

Description

The parameters for using single or multi path configurations are incorrect in the start-up list and the channel parameter list.

 

In the channel parameter list the parameter

multi_path_configuration   0 # P-CHAN-00261

is incorrectly set for the use of multipath configurations.

 

Correct setting for multipath configuration:

Channel parameter list:

multi_path_configuration   1 # P-CHAN-00261

Activate the function:

configuration.tool_radius_comp.function  MULTI_PATH # P-CHAN-00550

Alternatively, the function can be activated in the start-up list:

configuration.channel[0].tool_radius_comp.function  MULTI_PATH # P-STUP-00080

 

Correct setting for single path configuration (default):

Delete both parameters in each of the lists.

Response

Class

2

Abort NC program processing.

Solution

Class

6

Correct the parameters concerned in the channel parameter list (or start-up list.)

Error type

1, Error message from NC program.