ID 90178
Illegal combination of parameters in multipath configuration. | |||
Description | The parameters for using single or multi path configurations are incorrect in the start-up list and the channel parameter list.
In the channel parameter list the parameter multi_path_configuration 0 # P-CHAN-00261
is incorrectly set for the use of multipath configurations.
Correct setting for multipath configuration: Channel parameter list: multi_path_configuration 1 # P-CHAN-00261
Activate the function: configuration.tool_radius_comp.function MULTI_PATH # P-CHAN-00550
Alternatively, the function can be activated in the start-up list: configuration.channel[0].tool_radius_comp.function MULTI_PATH # P-STUP-00080
Correct setting for single path configuration (default): Delete both parameters in each of the lists. | ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 6 | Correct the parameters concerned in the channel parameter list (or start-up list.) |
Error type | 1, Error message from NC program. | ||
| |||