ID 90065
Compensation movement found, enable contour masking process. | |||
Description | To detect contour violations in linear blocks, the direction of the programmed motion block is compared with the direction of the corrected motion block. If the directions are opposite, this means a contour violation. The movement opposite to the programmed direction is called compensation movement.
This type of motion was detected and the contour masking process activated. See [PROG// Section: Limits of TRC]
The principle of the outline fading out consists of removing the loop from the corrected path. For this purpose, the contour masking buffers a certain number of blocks corrected via the TRC. If the tool radius compensation recognizes a balance movement with active outline fading out, she marks the motion block and continues with the calculation of correction. | ||
Response | Class | 1 | Abort NC program processing. |
Solution | Class | 1 | Possibility: Modification of NC Program Possibility: Use a tool with a smaller radius |
Error type | 1, Error message from NC program. | ||
|