ID 70452
Activation of axis coupling not possible, because axis position is not initialized. | ||||
Description | With an axis where axis parameters P-AXIS-00436 and P-AXIS-00460 are set, the axis coupling was activated via the HLI (see FCT-A9), although the axis positions of the axes involved are not yet fully initialised (the fieldbus has not yet supplied actual values valid for all axes). | |||
Response | Class | 7 | Error message output, coupling is not activated. | |
Solution | Class | 6 | When activation the coupling wait until all axes get valid actual positions from the fieldbus. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of the target axis of the coupling | ||||
%2: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of a source axis of the coupling | ||||
%3: | Current value [-] | |||
Indication whether the axis in value 2 gets valid actual positions from the fieldbus. | ||||
%4: | Current value [-] | |||
| ||||
Error type | - | |||
| ||||