ID 70380
Maximum permissible path exceeded for zero pulse search or encoder overflow search. | ||||
Description | During homing, the maximum permissible path set in parameter P-AXIS-00404 for searching the zero pulse or the encoder overflow was exceeded. Possible reasons for this error message are:
| |||
Response | Class | 7 | Stop of axis, output of error message. | |
Solution | Class | 6 | Possible solutions:
| |
Parameter | %1: | Logical axis number [-] | ||
Axis number (P-AXIS-00016). | ||||
%2: | Current value [-] | |||
Maximum permissible path during zero pulse search (value of P-AXIS-00404) | ||||
%3: | Limit value [-] | |||
Covered distance since start of zero pulse search. | ||||
%4: | Current value [-] | |||
Current actual axis position in increments. | ||||
%5: | Current value [-] | |||
Axis position at start of zero pulse search in increments. | ||||
Error type | 1, Error message from NC program. | |||
| ||||