ID 70243
Invalid resolution of slave axis for plane compensation. | ||||
Description | The compensation values for plane compensation were specified in increments in the corresponding compensation value list. This is only permitted for a measuring system path resolution of one (see P-AXIS-00234, P-AXIS-00233). However, the slave axis (the axis, which has to be compensated) uses a different path resolution than one.
See [COMP// Section: Plane compensation] and [FCT-C5//Plane compensation] | |||
Response | Class | 7 | Closed-loop controlled axis stop and turn off the plane compensation for the affected axis | |
Solution | Class | 7 | Change the value of parameter P-COMP-00008 in the compensation value list to one and enter the compensation values metrically (in 0.1 µm). | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of the affected slave axis see P-AXIS-00016 | ||||
%2: | Error value [-] | |||
Path resolution of measuring system of slave axis, see P-AXIS-00233, P-AXIS-00234 | ||||
%3: | Expected value [-] | |||
Expected path resolution of the measuring system, see P-AXIS-00233, P-AXIS-00234 | ||||
Error type | 11, Error message from position controller. | |||
|