ID 70207
Error reaction (cnc_controlled_stop_after_error) of master/ slave axis is different. | ||||
Description | The axis parameters contain different error reactions for the gantry master and slave axis. It is possible to choose between drive-internal and CNC-controlled error reaction (see P-AXIS-00254). For gantry mode, the same setting must be used for the master and slave axes.
See also FCT-C11// Section: Overview] | |||
Response | Class | 1 | Warning | |
Solution | Class | 1 | Use the same error reaction (see P-AXIS-00254) for both axes. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of the slave axis, see P-AXIS-00016 | ||||
%2: | Error value [-] | |||
Error reaction of the slave axis, see P-AXIS-00254 | ||||
%3: | Corrected value [-] | |||
Expected value for error reaction, see P-AXIS-00254 | ||||
Error type | - | |||
| ||||