ID 70207

Error reaction (cnc_controlled_stop_after_error) of master/ slave axis is different.

Description

The axis parameters contain different error reactions for the master and slave axis of the gantry combination. It is possible to choose between drive-internal and CNC-controlled error reaction (see P-AXIS-00254). For gantry mode, the same setting must be used for the master and slave axes.

 

See also FCT-C11// Section: Overview]

Response

Class

1

Warning

Solution

Class

1

Use the same error reaction (see P-AXIS-00254) for both axes.

Parameter

%1:

Logical axis number [-]

Logical axis number of the slave axis P-AXIS-00016

%2:

Error value [-]

Error reaction of the slave axis, see P-AXIS-00254

%3:

Corrected value [-]

Expected value for error reaction, see P-AXIS-00254

Error type

-