ID 60300
Motor or parameter set changeover during endless motion not allowed. | ||||
Description | An attempt was made to carry out a motor or parameter set changeover with the #DRIVE command during an active endless motion of a spindle. See [PROG// Section: Drive-independent switching of drive functions | |||
Response | Class | 6 | Error message output, abort program. | |
Solution | Class | 6 | While endless motion is active, it is not possible to change over a parameter set or the motor; change the NC Program. | |
Parameter | %1: |
| ||
| ||||
%2: | Error value [-] | |||
Motor number programmed in the #DRIVEcommand. A value of -1 means that the motor number was not programmed in the #DRIVE command. | ||||
%3: | Error value [-] | |||
Parameter set number programmed in the #DRIVE command. A value of –1 indicates that the parameter set number was not programmed in the #DRIVE command. | ||||
Error type | 1, Error message from NC program. | |||
| ||||