ID 50792

One linear and one circular block needed for circular area.

Description

A circular area consists of a linear block as starting point and a circular block as circular description. The second motion block after starting a definition of a circular area must be followed by a circular block as circle description.
See also [PROG// Monitoring the workspace and protection space]

 

Example with error:
%circular area
N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU…
N20 G01 X150 Y200 F10000
N30 G01 X150 Y200 F10000
N40 #CONTROL AREA END
N50 M30
Corrected example:
%circular area
N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU…
N20 G01 X150 Y200 F10000 (start point)
N30 G02 G162 I70 J150
N40 #CONTROL AREA END
N50 M30

 

Response

Class

6

Movement stop.

Solution

Class

6

Check and modify the area definition in the NC program

Parameter

%1:

Identification number [-]

Area ID

%2:

Error value [-]

Intersection of polygon lines

Error type

1, Error message from NC program.