ID 50781
The second block to define a circular area must be circular. | ||||
Description | The second motion block after starting a definition of a circular area must be a circular block for the circular description of the area. A circular area definition consists of two motion blocks, one linear at the starting point, and one circular to describe the circle. See also [PROG// Workspace and protection space monitoring] and [FCT-C14// Description].
Example:
%circular area
N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU…
N20 G01 X150 Y200 F10000
N30 G01 X150 Y200 F10000
N40 #CONTROL AREA END
N50 M30
(> error
Solution:
%circular area
N10 #CONTROL AREA START [ID51 PROT CIRC MIN_EXCU…
N20 G01 X150 Y200 F10000 (start point)
N30 G02 G162 I70 J150
N40 #CONTROL AREA END
N50 M30
(> correct) | |||
Response | Class | 6 | Movement stop. | |
Solution | Class | 6 | Check and modify the area definition in the NC program. | |
Parameter | %1: | Identification number [-] | ||
Area ID | ||||
Error type | 1, Error message from NC program. | |||
| ||||