ID 50774
Area not saved / active area cannot be overwritten. | ||||
Description | An attempt was made to overwrite an active area. Overwrite areas means to define an area with the same existing ID. See also [PROG// Defining a control area] and [FCT-C14// Description].
An area already exists with the commanded ID and it is currently activated. To overwrite an existing area, it should be inactive.
Example:
%areaoverwrite
N10 #CONTROL AREA ON [ID2]
N20 #CONTROL AREA BEGIN [ID2 WORK ……… (< error
Solution:
%areaoverwrite
N10 #CONTROL AREA ON [ID2]
N15 #CONTROL AREA OFF [ID2]
N20 #CONTROL AREA BEGIN [ID2 WORK.. (< overwrite | |||
Response | Class | 6 | Movement stop. | |
Solution | Class | 6 | Check and modify NC program; deactivate the area to be overwritten. | |
Parameter | %1: | Identification number [-] | ||
Area ID | ||||
Error type | 1, Error message from NC program. | |||
| ||||