ID 50726
The communication of the Volumetric Compensation does not work, because the channel contains no axis. | ||||
Description | This error occurs if a #VOLCOMP NC command is executed in a channel that does not contain an axis. For more information on volumetric compensation, see [FCT-C26] | |||
Response | Class | 2 | Stopping the axis, and aborting the NC program. | |
Solution | Class | 3 | Before executing the NC command The communication of the Volumetric Compensation does not work, because the channel contains no axis. add an axis to the axes in the channel and reset the CNC. | |
Parameter | %1: | Logical channel number [-] | ||
Channel number | ||||
%2: | Identification number [-] | |||
ID of the Volumetric Compensation | ||||
Error type | 1, Error message from NC program. | |||
| ||||