ID 50449
Start of storage reached during backward movement, no further backward movement possible. | ||||
Description | With the backward motion on the path function, the maximum number of backward motion blocks depends on available memory size P-STUP-00033. With very large NC programs, it may occur that the memory is unable to save all forward direction motion blocks. For more information on backward motion, see [FCT-C7// Section: Forward/backward motion on the path] The first parameter in the error message indicates whether it is no longer possible to continue backward motion due to axis positions that were changed outside the NC program. Axis positions which are changed by real-time influences cannot be considered in backward motion since they are not a component of the planned path. Real-time influences that can prevent backward motion include:
| |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Increase size of backward motion memory P-STUP-00033. | |
Parameter | %1: | Current value [-] | ||
TRUE if further backward motion is not possible due to axis positions changed outside the NC program. | ||||
Error type | 1, Error message from NC program. | |||
| ||||