ID 50053
Received probe before reaching the measuring motion block. | ||||
Description | When using the measurement function G100, different measurement types can be completely contoured in the measurement block.. For preparation of probe hardware the measurement process in CNC is activated in previous movement block. In this case the probe sensor can be activated before moving in measure movement block. For detailed information on measurement function G100, see[FCT-C4], [PPROG// Section: Measuring functions]. | |||
Response | Class | 4 | Movement stop. | |
Solution | Class | 6 | Either use measurement type with motion stop or program special MOS M/H function in the measurement motion block and check the measuring sensor logic in the PLC before enable. | |
Parameter | %1: | Upper limit value [-] | ||
| ||||
%2: | Upper limit value [-] | |||
| ||||
%3: | Block number [-] | |||
| ||||
%4: | Upper limit value [-] | |||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||